1. Before the installation and construction of the hot-melt pipe, you must first check the qualification certificate of the fusion splicer in detail to ensure that you are purchasing a qualified product, and also read the product instruction manual in detail to make sure you know the detailed correct operation steps. The installation and construction of the hot melt pipe can be started.
2. During the installation and construction of the hot-melt pipe, a pen and a ruler should be used to mark the hot-melt depth on the surface of the pipe, and the hot-melt time should be recorded clearly, so as to avoid the occurrence of hot-melt overtime and affect the hot-melt effect. .
3. After the hot-melt time is up, the pipes and fittings need to be removed from the heating film in time, and they need to be inserted to the marked depth in time, and they should be adjusted in a short time to make them in the right position and at the right angle.
4. After the installation and construction of the hot-melt pipe is completed, the water test test of the pipeline cannot be carried out immediately. It should wait for one day after installation before the water test test can be carried out. Exclude clean.